HY-DEL

Hybrid Cooling Unit

Hybrid unit is a system that combines Evaporative cooling & Refrigerated Air Conditioning for smooth year-round operation.

It has all the benefits of DUO-DEL. It has additional Refrigerant (DX) coil.

All the components in the system can be automatically operated using Smart Control based on ambient & indoor conditions.

DUO-DEL

Two-Stage Evaporative Cooling Unit

A combination of our specialized Sensible heat exchanger (CT-SHX / PT-SHX) and Adiabatic heat
exchanger (AHX), provides better efficiency over conventional (single stage) evaporative cooling.

Supply air stream is first pre-cooled by Indirect Evaporative Cooling which reduces the DBT & WBT of air without addition of moisture.

It is then passed through Adiabatic Heat Exchanger (cellulose pad), further reducing the temperature of air even below the ambient WBT.

https://www.deltat.co.in/wp-content/uploads/2023/05/4.png

Floor Mounted Horizontal /
Vertical Air Handling Unit

Horizontal floor mounted Air Handling Units (AHUs) are the most common type of units used for supplying Treated & filtered air to the conditioned area.

Air treatment can be any process from Cooling/ Heating/ Humidification / Dehumidification / Combination of above.

https://www.deltat.co.in/wp-content/uploads/2023/05/1-1.png
https://www.deltat.co.in/wp-content/uploads/2023/05/12.png

SMART AHUs

AHU with integrated control system to overcome the need of building management systems which can be controlled remotely and linked to automation systems with standard communication protocols support.

Ceiling Suspended
Air Handling Units

Ceiling Suspended AHUs are most commonly used for supplying the treated air to individual or small space where dedicated floor space is a constrained .

https://www.deltat.co.in/wp-content/uploads/2023/05/3-1.png
https://www.deltat.co.in/wp-content/uploads/2023/05/2-1.png

Treated Fresh Air Unit

Treated Fresh Air units are used to suffice the requirement of fresh air to the conditioned space making sure to maintain the degree of comfort for human living as per ISHRAI / ASHRAE standards.

Pre-Cooling Unit

Pre-Cooling units are used to pre cool the entering air with the help of Sensible Heat Exchanger (CT-SHX / PT-SHX).

After passing through CT-SHX / PT-SHX, air can either be supplied direct or further conditioned based on final requirement.

This unit drastically reduces the load of Air Conditioner for areas operating with high fresh air.

https://www.deltat.co.in/wp-content/uploads/2023/05/6.png
https://www.deltat.co.in/wp-content/uploads/2023/05/7.png

Single Stage Air Washer Unit

Single Stage Air Washer Units work on a principle of Adiabatic Cooling of air which is relatively economical & suitable cooling solution for the dry climate conditions.

Cooling of air takes place due to the evaporation of water circulating through a medium (usually cooling pad) which comes in direct contact with the coming air.

Wet Scrubber

Wet Scrubbers are generally used to remove the suspended solid/liquid particles in air coming from the conditioned space.

These unit scrubs/washes away the air suspended particles of oil/grease/ash, which is collected at the bottom of the section and air free from all those particles is exhausted to
atmosphere. 

https://www.deltat.co.in/wp-content/uploads/2023/05/8.png
https://www.deltat.co.in/wp-content/uploads/2023/05/9.png

Pressurization / Ventilation Unit

Pressurization / Ventilation Units are used to add / remove air to / from conditioned area to meet the desired design requirements.

Heat Recovery Unit

Heat Recovery Units are basically used to recover the heat from return air stream and supply the same to supply air stream.

Heat Recovery can be achieved either by steady component (Plate type heat exchanger) or rotating component (Heat recovery wheel).

Ultimately reduces over-all air conditioning load of a building.

https://www.deltat.co.in/wp-content/uploads/2023/05/10.png
https://www.deltat.co.in/wp-content/uploads/2023/05/11.png

Fan Coil Units (FCUs)

FCUs are most commonly used for supplying the recirculated air and are directly to conditioned room without the supply duct work.